Monolith Housing Solution

|

Surrey Home Energy and Comfort Assessment

Home Energy and Comfort Assessment in Surrey

Some rooms too warm, others too cold, a basement that never smells quite right, and a list of planned renovations with no clear order. Instead of a standard home energy audit alone, Monolith Housing Solutions combined energy modelling, field testing, thermal imaging and ventilation diagnostics into one investigation of a large multi-level home in Surrey.

Project Snapshot

Project: Residential energy, ventilation and building-performance assessment

Location: Surrey, British Columbia

Home: Large multi-level residential property

Concerns: Uneven temperatures, upper-floor comfort, persistent basement odour, unclear upgrade order

Service: Integrated energy, airtightness, thermography, ventilation and sizing assessment

Deliverable: A prioritized renovation and electrification roadmap

Exterior of the Surrey home assessed by Monolith Housing Solutions

Diagnostics

Matching Each Concern to the Right Diagnostic

Comfort and air-quality complaints rarely have a single cause, so each tool was chosen to answer one part of the problem.

Diagnostic

What it helped answer

EnerGuide evaluation

How the home performs as a whole and where energy is going

Blower door test

How much uncontrolled air moves through the enclosure

Infrared thermal imaging

Where heat loss and leakage show up in walls, ceilings, windows and service areas

Exhaust airflow and pressure-pan tests

Whether bath fans remove moist air and where duct connections leak

Whole-house depressurization

How the house responds when exhaust equipment pulls air out

CSA F280 calculations

Room-by-room heat loss and gain for correct equipment sizing

Findings

Where the Assessment Found Opportunities

1

Envelope

Window performance, attic insulation and air sealing.

2

Air Movement

Exhaust duct connections and airflow distribution through the home.

3

Systems and Spaces

Crawlspace conditions and mechanical-system sizing.

Infrared image of an interior wall showing temperature variation

Sizing the Heat Pump Around the Future House

The owners were planning envelope upgrades that would lower heating and cooling loads. Sizing on today's loads would risk an oversized system once the work was done.

CSA F280 heat loss calculations modelled sizing for the planned upgrades, with and without heat recovery.

Turning Findings Into a Renovation Sequence

Monolith brought the findings into one upgrade strategy so the heat pump, ventilation and envelope work could be designed as one connected system rather than separate renovations booked in whatever order they came.

Infrared image showing a warm vertical line inside a wall
Retrotec readings on a phone during the whole-house depressurization test

Why an Integrated Assessment Works Better

  1. Symptoms traced to causes from several directions.
  2. Equipment sized correctly for the upgraded home.
  3. Money spent in the right order.
  4. Comfort and air quality solved together.

Living With Comfort Problems in Surrey?

If your home in Surrey, Langley, Delta or elsewhere in the Lower Mainland has rooms that never feel right, or you are planning a heat pump and envelope upgrades, Monolith Housing Solutions can investigate before you commit.

(604) 723-1364

2030 Marine Dr, North Vancouver, BC

Contact Us

Project Media

Inside the Assessment

The home, blower door and exhaust airflow testing, and infrared images from the assessment.

Exterior of the Surrey home assessed by Monolith Housing Solutions Blower door fan installed in the front entrance of the Surrey home Exhaust airflow measurement on a bathroom ceiling fan in the Surrey home Retrotec readings on a phone during the whole-house depressurization test Infrared image of an interior wall showing temperature variation Infrared image showing a warm vertical line inside a wall